    RTI Dose Probe

    For Low Dose Rate Measurements

    The RTI Dose Probe is an external dose probe, designed to perform very low dose rate measurements for instance on image intensifiers.
    To avoid or minimize interference with AEC (Automatic Exposure Control) on X-ray equipment, the probe is very small. This also enables to fit it into the table bucky. Since it is a solid-state detector, no corrections for pressure or temperature are needed. Neither is bias voltage.

    Fluoroscopy

    The RTI Dose Probe is small and has a fast response which makes it ideal for pulsed fluroscopy. It can detect the individual pulses, determine pulse rate and show waveforms even at the highest pulse rates used on modern fluoroscopy systems and be used both for continuous and pulsed fluroroscopy. This is not possible with ionization chambers since their response is too slow to resolve individual pulses.

    The RTI Dose Probe supports the ADI (automatic detector identification) system. When connected, the Piranha or Cobia automatically identifies the probe and makes all necessary adjustments without any need for interaction from the user. The Piranha ADI system also gives full interchangeability of probes between different Piranha systems using the same type of probes.

    With the extra ordinary sensitivity of the Dose Probe it is even suitable for scatter and leakage measurements.

     

     

     

     

     

     

     

     

     

     

    Beam quality - W/3 mm A

    Specifications with Black Piranha

    Type  R100B
    Sensitivity  55 µC/Gy
    Size  20 x 45 x 7.4 mm, 0.79" x 1.8" x 0.29"
      Weight 85 g (3 oz)
    Active detector area 10 x 10 mm, 0.39" x 0.39"
    Cable length 2.0 m (6.6 ft)
    Connector  Piranha type with automatic detector identification
    Dose range  0.1 nGy - >1.5 kGy
      12 nR - >170 kR
    Dose rate range  1 nGy/s - 76 mGy/s
      0.4 mR/h - 31 kR/h
    Dose per pulse  1 nGy/pulse - 3 kGy/pulse
      120 nR/pulse - 340 kR/pulse
    Backscatter protected 
    Yes

     

    Specifications with Cobia Flex / Sense 

    Type  R100B
    Inaccuracy  ± 5%
    Size  20 x 45 x 7.4 mm, 0.79" x 1.8" x 0.29"
    Weight 85 g (3 oz)
    Cable length  2.0 m (6.6 ft)
    Pulse frequency  1/6 - 260 Hz
    Dose   5 nGy - 2 kGy 
      0.6 µR - 250 kR
    Dose rate   0.2 µGy/s - 200 mGy/s
      1.5 mR/min - 1.5 kR/min
    Dose per pulse 1 nGy/pulse - 1600 mGy/pulse
      0.1 µR/pulse - 180 R/p 
    Backscatter protected Yes

     

    Article Nr: 9730003-00

    Download Brochure

    Size 320513 B

    Related Products

    © Copyrighted RTI Group AB 2016 Privacy Policy|Cookies