Piranha MAMMO

$10,197.00

For Mammography measurements. All you need to take QA measurements for any 2D or 3D X-ray system in hospitals or mammography clinics. Measures kVp, Time, HVL, Total Filtration, Dose, Dose rate, and presents Waveform.

Included: 10″ Tablet PC, internal rechargeable battery, Internal Bluetooth & USB port, USB cable, Ocean Next™ software with Advantage license, Power supply, USB Stick, Soft-Shell transport case and Basic online training.

Read about our pre-paid calibration and extended warranty.

All prices include freight cost. Pricing does not include Applicable Taxes or Customs Fees.

The ultimate solution for Mammo QA testing

The Piranha MAMMO is the ultimate solution designed by experts for anyone working with specialist diagnostic X-ray technology in hospitals or mammography clinics. It measures kVp, time, HVL, Dose, Dose rate, and presents Waveforms.

You get extremely accurate measurements that you can then use for your in-depth analyses. All the measurements are transmitted wireless to your Ocean software for analysis, storage, and reports in one smooth process.

With the Piranha Mammo, you have a compact solution for fast and reliable testing. You can be sure of extremely accurate measurements that can be used for in-depth analysis.

Ocean Next™ software
Its compatibility with our Ocean Next™ software provides quick and repeatable QA work. Ocean can perform instant real-time analysis during your measurements. Use your tablet/laptop as both an interactive display during the measurements and as a powerful analysis tool when you are back at the office.

All your measurements, along with the result and the report, will be stored inside your tablet or laptop; there is no unnecessary, time-consuming data transfer.

A complete QA solution instantly
The Piranha MAMMO comes ready-to-use with everything you need included. It really is an all-in-one multifunction meter. Connect to your computer wireless or via USB and you have a complete QA system!

Position check
The unique feature of the Piranha MAMMO makes it possible to check the position of the detector before measuring. By using the “Position Check” function, you can verify that the detector area is fully irradiated. Possible field inhomogeneities are also neutralized.

Piranha MAMMO key features

  • All-in-one multifunction X-ray meter
  • One-shot HVL
  • Solid-state detectors = no need to compensate for temperature & pressure
  • Can measure on scanning beams as well as tomosynthesis
  • Optimized for X-ray equipment from a large number of manufacturers
  • Built-in energy compensation
  • Can be used together with ion chambers
  • Automatic recognition of external probes
  • Small, compact, and robust – easy to place
  • Backscatter protected
  • Long-lasting rechargeable battery
  • Always free firmware upgrades
  • Upgradable to any Piranha model
  • Up to ten-year warranty
  • Two-year Calibration Cycle

General specifications Piranha

  • Size
    133x75x26 mm
  • Weight
    Approx. 400 g
  • Display
    PC or Windows Tablet
  • Software
    Ocean - Complete Software for X-ray QA
  • DatabaseSupport
    Yes
  • Interface Type
    Built-in Bluetooth and USB
  • Detector Position Check
    Yes
  • Simultaneous Dose Measurements
    Yes - up to two detectors simultaneously
  • Use of Dose Detector with Active AEC
    Yes - RTI Dose Probe or RTI T20
  • Bluetooth range
    100 m free-in-air
  • USB Cables
    Included
  • Power source
    Rechargable Li ion battery / Ext. power supply
  • Battery life
    Approx. 15 hours
  • Battery tested
    According to UN 38.3
  • No. of Exposures Needed for Measurement
    One
  • Min. Exposure Time
    0.1 ms
  • Memory
    Unlimited
  • Operating temperature
    15 °c – 35 °c
  • Storage temperature
    -10 °c - +50°c
  • Waveform Sampling rate
    4 – 2000 samples/s
  • Waveform recording time
    1024 ms – 524 s
  • Backscatter Protection
    Yes - main unit, RTI Dose Probe, and T20
  • Warranty
    Two years
  • Extended Warranty
    Up to 10 years
  • Calibration Cycle
    Two years
  • Standard
    Complies with relevant parts of the standards IEC 61674 and IEC 61676 for Dosimetric instruments
  • EMC Tested
    According to IEC 61326-1:2012
  • PTB Approval
    DE-17-M-PTB-0070

Piranha - Specifications for Mammography

  • Tube Voltage
  • Target Filter: W / Ti
    Range: 40-49kV
    Inaccuracy: ±0,5kV or ±1,5%
  • Target/Filter: Mo / 30 μm Mo.
    Range: 18 – 49 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target/Filter: Mo / 25 μm Rh.
    Range: 20 – 46 kV.
    Inaccuracy: ±1 kV.
  • Target Filter: Rh / 25 μm Rh.
    Range: 25 – 49 kV.
    Inaccuracy: ±1 kV.
  • Target Filter: Rh / 1.0 mm Al.
    Range: 22 – 35 kV.
    Inaccuracy: ±1 kV.
  • Target Filter: W / 50 μm Rh.
    Range: 20 – 49 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %.
  • Target Filter: W / 0.50 mm Al.
    Range: 20 – 48 kV.
    Inaccuracy: ±1 kV.
  • Target Filter: Mo / 1.0 mm AI.
    Range: 18 – 49 kV.
    Inaccuracy: ±1 kV.
  • Target Filter: W / 50 μm Ag.
    Range: 20 – 40 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: W / 75 μm Ag.
    Range: 20 – 40 kV.
    Inaccuracy: ±1 kV.
  • Target Filter: W / 50 μm Rh (Gio).
    Range: 22 – 35 kV.
    Inaccuracy: ±1 kV.
  • Target Filter: W / 0.70 mm Al.
    Range: 20 – 49 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: W / 50 μ m Ag (Sel).
    Range: 22 – 39 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: W / 50 μ m Rh (Sel).
    Range: 22 – 39 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: W / 0.30 mm Cu.
    Range: 40 – 49 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: W / 0.70 mm Al (Inno/Crist).
    Range: 20 – 49 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: W / 50 μ m Rh (Inno/Crist)
    Range: 20 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: Mo / 25 μ m Rh (Sel)
    Range: 20 – 46 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: Rh / 30 μm Ag (GE)
    Range: 27 – 40 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: Rh / Ag IQST (GE)
    Range: 31 – 37 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: Mo / 0.25 mm Cu (GE)
    Range: 40 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: Rh / 0.25 mm Cu (GE)
    Range: 40 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter:Mo / 30 μm Mo (GE)
    Range: 22 – 32 kV
    Inaccuracy: ±1 kV
  • Target Filter: Affirm Prone W / 50 μm Ag
    Range: 20 – 40 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Target Filter: Affirm Prone W / 0.70 mm Al.
    Range: 20 – 49 kV.
    Inaccuracy: ±0.5 kV or ±1.5 %
  • Time
    0.1 ms – 2000 s (±0.5 % or ±0.5 ms)
  • Dose
    1 nGy – 1000 Gy. 3 µR – 150 kR (±5 %)
  • Dose Rate
    25 nGy/s – 530 mGy/s (±5 % or ±12 nGy/s)
    30 μR/s – 60 R/s (±5 % or ±1.5 μR/s)
  • HVL Range
    0.19 – 4.3 mm Al (depending on Target/Filter combination) (±10 %)
  • Pulses
    1 – 65535 pulses (±1 pulse)