Piranha Premium Kit
The all-in-one complete solution for QA testing
All our Piranha Premium Kis are based on a Piranha MULTI along with a number of its probes and accessories, well-organized and safely stored in a robust, aluminum case. All our Piranha Premium kits are available at a discounted price.
The Piranha Premium Kit MULTI with associated probes is all you need for qualified diagnostics. Bring your case to any Rad/Fluoro, CT, Dental, and Mammography X-ray unit and perform your work without missing any item. It measures kVp, Time, HVL, Total Filtration, Dose, Dose rate, and presents Waveform.
Read about our pre-paid calibration and extended warranty.
$24,938
A complete QA solution
Get your favorite holders and probes neatly packaged in a case. Connect your system to your computer wirelessly or via USB and you have a complete QA solution.
Wide range of probes & accessories
DAP, holders, CT Ion Chamber, CTDP, Light Probe together with Ocean Nextâ„¢ software.
Ocean Nextâ„¢ software
Its compatibility with our Ocean Nextâ„¢ software provides quick and repeatable QA work. Ocean can perform instant real-time analysis during your measurements. Use your tablet/laptop as both an interactive display during the measurements and as a powerful analysis tool when you are back at the office.
- All-in-one multifunction X-ray meter
- One-shot HVL
- Solid-state detectors = no need to compensate for temperature & pressure
- Can measure on scanning beams as well as tomosynthesis
- Optimized for X-ray equipment from a large number of manufacturers
- Built-in energy compensation
- Can be used together with ion chambers
- Wide-range detection of total filtration
- 100 meters Bluetooth range
- Automatic recognition of external probes
- Small, compact, & robust – easy to position
- Backscatter protected
- Long-lasting rechargeable battery
- Always free firmware upgrades
- Up to ten-year warranty
- Two-year calibration cycle
- Unique detector design to minimize position and rotation dependence
-
Size 133 x 75 x 26 mm Weight Approx. 400 g Display PC or Windows Tablet Software Ocean Next™ software for X-ray QA Database support Yes Interface type Built-in Bluetooth and USB Detector Position Check Yes Simultaneous Dose Measurements Yes - up to two detectors simultaneously Use of Dose Detector with Active AEC Yes - RTI Dose Probe or RTI T20 Bluetooth range 100 m free-in-air USB cables Included Power source Rechargeable Li ion battery / Ext. power supply Battery life Approx. 15 hours Battery tested According to UN 38.3 No. of exposures needed for measurement One Min. exposure time 0.1 ms Memory Unlimited Operating temperature 15 °c – 35 °C Storage temperature -10 °C - +50°C Waveform sampling rate 4 – 2000 samples/s Waveform recording time 1024 ms – 524 s Backscatter Protection Yes - main unit, RTI Dose Probe, and RTI T20 Warranty Two years Extended Warranty Up to ten years Calibration Cycle Two years Standard Complies with relevant parts of the standards IEC 61674 and IEC 61676 for Dosimetric instruments EMC Tested According to IEC 61326-1:2012 PTB Approval DE-17-M-PTB-0070 -
Tube Voltage 35 – 160 kV (±1.5 %) PPV Yes Time 0.1ms – 2000 s (±0.5 % or ±0.5 ms) Dose 1.3 nGy – 650 Gy. 150 nR – 74 kR. (±5 %) Dose Rate 15 nGy/s – 320 mGy/s (±5 % or ±7 nGy/s)
1.7 μR/s – 37 R/s (±5 % or ±0.8 μR/s)Auto Compensation All dose parameters are automatically compensated for using measured kVp and TF over their specified ranges. HVL 0.72 – 13 mm Al (±10 % or ±0.2 mm) Total Filtration 1.0 – 90 mm Al (±10 % or ±0.3 mm) Pulses 1 – 65535 pulses (±1 pulse) Dose/pulse 8 nGy/pulse – 0.9 Gy/pulse Pulse Rate/Frequency 0.5 – 180 Hz Pulse width 4 ms – 2000 s -
Tube Voltage Target/Filter: Mo / 30 μm Mo
Range: 18 – 49 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target/Filter: Mo / 25 μm Rh
Range: 20 – 46 kV
Inaccuracy: ±1 kVTarget Filter: Rh / 25 μm Rh
Range: 25 – 49 kV
Inaccuracy: ±1 kVTarget Filter: Rh / 1.0 mm Al
Range: 22 – 35 kV
Inaccuracy: ±1 kVTarget Filter: W / 50 μm Rh
Range: 20 – 49 kV
Inaccuracy: ±0.5 kV or ±1.5 %0,Target Filter: W / 0.50 mm Al
Range: 20 – 48 kV
Inaccuracy: ±1 kVTarget Filter: Mo / 1.0 mm AI
Range: 18 – 49 kV
Inaccuracy: ±1 kVTarget Filter: W / 50 μm Ag
Range: 20 – 40 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: W / 75 μm Ag
Range: 20 – 40 kV
Inaccuracy: ±1 kVTarget Filter: W / 50 μm Rh (Gio)
Range: 22 – 35 kV
Inaccuracy: ±1 kVTarget Filter: W / 50 μm Rh (Gio)
Range: 22 – 35 kV
Inaccuracy: ±1 kVTarget Filter: W / 0.70 mm Al
Range: 20 – 49 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: W / 50 μ m Ag (Sel)
Range: 22 – 39 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: W / 50 μ m Rh (Sel)
Range: 22 – 39 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: W / 0.30 mm Cu
Range: 40 – 49 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: W / 0.70 mm Al (Inno/Crist)
Range: 20 – 49 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: W / 50 μ m Rh (Inno/Crist)
Range: 20 – 49 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: Mo / 25 μ m Rh (Sel)
Range: 20 – 46 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: Rh / 30 μm Ag (GE)
Range: 27 – 40 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: Rh / Ag IQST (GE)
Range: 31 – 37 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: Mo / 0.25 mm Cu (GE)
Range: 40 – 49 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: Rh / 0.25 mm Cu (GE)
Range: 40 – 49 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter:Mo / 30 μm Mo (GE)
Range: 22 – 32 kV
Inaccuracy: ±1 kVTarget Filter: Affirm Prone W / 50 μm Ag
Range: 20 – 40 kV
Inaccuracy: ±0.5 kV or ±1.5 %Target Filter: Affirm Prone W / 0.70 mm Al
Range: 20 – 49 kV
Inaccuracy: ±0.5 kV or ±1.5 %Time 0.1 ms – 2000 s (±0.5 % or ±0.5 ms) Dose 1 nGy – 1000 Gy. 3 µR – 150 kR (±5 %) Dose Rate 25 nGy/s – 530 mGy/s (±5 % or ±12 nGy/s)
30 μR/s – 60 R/s (±5 % or ±1.5 μR/s)HVL Range 0.19 – 4.3 mm Al (depending on Target/Filter combination) (±10 %) Pulse 1 – 65535 pulses (±1 pulse) -
Tube Voltage 45 – 155 kV (±1.5 %) Time 0.1 ms – 2000 s (±0.5 % or ±0.5 ms) Total Filtration 1 – 90 mm Al (±10 % or ±0.3 mm) HVL 1.2 – 14 mm Al (±10 % or ±0.2 mm) Pulses 1 – 65535 pulses (±1 pulse) -
Tube Voltage 35 – 125 kV (±1.5 %) PPV Yes Time 0.1ms – 2000 s (±0.5 % or ±0.5 ms) Dose 1.3 nGy – 650 Gy. 150 nR – 74 kR. (±5 %) Dose Rate 15 nGy/s – 320 mGy/s (±5 % or ±7 nGy/s). 1.7 μR/s – 37 R/s (±5 % or ±0.8 μR/s) Auto Compensation All dose parameters are automatically compensated for using measured kVp and TF over their specified ranges. HVL 1.2 – 14 mm Al (±10 % or ±0.2 mm) Total Filtration 1.0 – 90 mm Al (±10 % or ±0.3 mm) Pulses 1 – 65535 pulses (±1 pulse) Dose/pulse 8 nGy/pulse – 0.9 Gy/pulse Pulse Rate/Frequency 0.5 – 180 Hz Pulse width 4 ms – 2000 s -
Size 20 x 45 x 7.4 mm, 0.79" x 1.8" x 0.29" Weight 85 g (3 oz) Cable length 2.0 m (6.6 ft) Backscatter protected Yes Dose 100 pGy – 1.5 kGy. 12 nR – 170 kR (± 5%) Dose Rate 4 nGy/s – 150 mGy/s (±5 % or ±10 nGy/s).
0.46 μR/s – 16 R/s (±5 % or ±1 μR/s).
26 μR/min – 1000 R/min (±5 % or ±6 μR/min).Time 0.1 ms – 34000 s (±1 % or ±0.5 ms) Pulses 1 – 65535 pulses (±1 pulse) Dose per pulse 1 nGy/pulse – 0.3 Gy/pulse Pulse rate/frequency 0.5 – 100 Hz Pulse width 4 ms - 2000 s -
Type MAS-1B Current range 0.1–3000 mA Inaccuracy ±1 % or ±0.01 mA Frequency range DC–500 Hz (-3 dB) Size 60 x 35 x 72 mm Weight 125 g Battery life Around 100 h Rechargeable battery With mini-USB connector Cable length 4 m (extension available) Connector Hirose -
Type MAS-2 Current range 10 - 4000 mA Inaccuracy ±5 % or ±2 mA (±3 % at 250 mA) Charge range 0.1 mAs - 9999 mAs Size 183 x 61 x 36 mm Connector Hirose Maximum cable diameter 24 mm Power source 9 V "6LR61" Alkaline battery -
Dose rate range 67 nGy/s-2.2 Gy/s. 0.46 mR/min - 15000 R/min Inaccuracy ±5 % or ±15 nGy/s Spatial resolution 0.25 mm -
Air kerma rate 0.3 mGycm/s to 3 Gycm/s Inaccuracy ±5 % or ±0.03 mGycm/s Connector type LEMO triaxial Cable 2 m, low noise triaxial Active volume 16 cm³ Active length 300 mm Diameter 12 mm, 12.6 incl O-rings Typical leakage ±20 fA Radiation quality 70 - 150 kV Sensitivity 30 mGycm/nC Energy Dependence ±1 %
LoniMoverâ„¢
Measure CTDI for Wide Beam and Cone Beam CT! Together with the RTI CT Ion Chamber or CT Dose Profiler, the RTI LoniMoverâ„¢ is, without a doubt, the easiest and most accurate way to measure CTDI and waveforms for Wide Beam and Cone Beam CT. With the CT Dose Profiler, you will get the FWHM, [...]
Read moreCTDI Phantom Set
Adapt the size of the phantom RTI CTDI Phantom Sets simulates adult and pediatric head and body of patients for QA testing of Âcomputed tomography (CT) systems. RTI offers two different CTDI Phantom sets. Choose two (2) or three (3) parts. Both have nested modules to allow adaptation to the size required by the selected [...]
Read morePiranha Panoramic Holder/Vertical Holder v.4
Attach your Piranha vertically The Piranha Panoramic Holder/Vertical Holder v.4 is designed for attaching the Piranha DENTAL meter to dental panoramic equipment or vertical mounting. It can be mounted with an adjustable strap or magnets. [...]
Read more10" Tablet PCÂ
Connect wirelessly! Microsoft Surface Go 3 10″ Tablet PC display for wireless or USB communication with the Piranha, Mako and Cobia meters. The portable tablet comes with a detachable keyboard, Windows 11 Home, installed Ocean Nextâ„¢ software, built-in Bluetooth, a charger, and all necessary items to make it a user-friendly & versatile [...]
Read more