Piranha Premium Kit

The all-in-one complete solution for QA testing

All our Piranha Premium Kis are based on a Piranha MULTI along with a number of its probes and accessories, well-organized and safely stored in a robust, aluminum case. All our Piranha Premium kits are available at a discounted price.

The Piranha Premium Kit MULTI with associated probes is all you need for qualified diagnostics. Bring your case to any Rad/Fluoro, CT, Dental, and Mammography X-ray unit and perform your work without missing any item. It measures kVp, Time, HVL, Total Filtration, Dose, Dose rate, and presents Waveform.

Read about our pre-paid calibration and extended warranty.

All prices include freight cost.

Prices do not include applicable taxes or customs fees. Please check your local import requirements.

Add Voucher Code in the cart.

$24,938

$24,938
Included: Dose Probe for input dose to image intensifiers, scattered and leakage radiation. Light Probe for measurements on monitors and for measurement of ambient light. CT Dose Profiler for CTDI measurements. MAS-1 for invasive mA and mAs. Ocean Next Software with Professional license, Aluminum Case and Basic online training. Standard two-year warranty/calibration.
$24,938
Included: Dose Probe for input dose to image intensifiers, scattered and leakage radiation. Light Probe for measurements on monitors and for measurement of ambient light. RTI CT Ion Chamber and Chamber Adapter for CTDI measurements. MAS-1 for invasive mA and mAs. Ocean Next Software with Professional license, Aluminum Case and Basic online training. Standard two-year warranty/calibration.
$24,938
Included: Dose Probe for input dose to image intensifiers, scattered and leakage radiation. Light Probe for measurements on monitors and for measurement of ambient light. CT Dose Profiler for CTDI measurements. MAS-2 for non-invasive mA and mAs. Ocean Next Software with Professional license, Aluminum Case and Basic online training. Standard two-year warranty/calibration.
$24,938
Included: Dose Probe for input dose to image intensifiers, scattered and leakage radiation. Light Probe for measurements on monitors and for measurement of ambient light. RTI CT Ion Chamber and Chamber Adapter for CTDI measurements. MAS-2 for non-invasive mA and mAs. Ocean Next Software with Professional license, Aluminum Case and Basic online training. Standard two-year warranty/calibration.

A complete QA solution

Get your favorite holders and probes neatly packaged in a case. Connect your system to your computer wirelessly or via USB and you have a complete QA solution.

Wide range of probes & accessories

DAP, holders, CT Ion Chamber, CTDP, Light Probe together with Ocean Nextâ„¢ software.

Ocean Nextâ„¢ software

Its compatibility with our Ocean Nextâ„¢ software provides quick and repeatable QA work. Ocean can perform instant real-time analysis during your measurements. Use your tablet/laptop as both an interactive display during the measurements and as a powerful analysis tool when you are back at the office.

  1. All-in-one multifunction X-ray meter
  2. One-shot HVL
  3. Solid-state detectors = no need to compensate for temperature & pressure
  4. Can measure on scanning beams as well as tomosynthesis
  5. Optimized for X-ray equipment from a large number of manufacturers
  6. Built-in energy compensation
  7. Can be used together with ion chambers
  8. Wide-range detection of total filtration
  9. 100 meters Bluetooth range
  10. Automatic recognition of external probes
  11. Small, compact, & robust – easy to position
  12. Backscatter protected
  13. Long-lasting rechargeable battery
  14. Always free firmware upgrades
  15. Up to ten-year warranty
  16. Two-year calibration cycle
  17. Unique detector design to minimize position and rotation dependence
  1. Size 133 x 75 x 26 mm
    Weight Approx. 400 g
    Display PC or Windows Tablet
    Software Ocean Nextâ„¢ software for X-ray QA
    Database support Yes
    Interface type Built-in Bluetooth and USB
    Detector Position Check Yes
    Simultaneous Dose Measurements Yes - up to two detectors simultaneously
    Use of Dose Detector with Active AEC Yes - RTI Dose Probe or RTI T20
    Bluetooth range 100 m free-in-air
    USB cables Included
    Power source Rechargeable Li ion battery / Ext. power supply
    Battery life Approx. 15 hours
    Battery tested According to UN 38.3
    No. of exposures needed for measurement One
    Min. exposure time 0.1 ms
    Memory Unlimited
    Operating temperature 15 °c – 35 °C
    Storage temperature -10 °C - +50°C
    Waveform sampling rate 4 – 2000 samples/s
    Waveform recording time 1024 ms – 524 s
    Backscatter Protection Yes - main unit, RTI Dose Probe, and RTI T20
    Warranty Two years
    Extended Warranty Up to ten years
    Calibration Cycle Two years
    Standard Complies with relevant parts of the standards IEC 61674 and IEC 61676 for Dosimetric instruments
    EMC Tested According to IEC 61326-1:2012
    PTB Approval DE-17-M-PTB-0070
  2. Tube Voltage 35 – 160 kV (±1.5 %)
    PPV Yes
    Time 0.1ms – 2000 s (±0.5 % or ±0.5 ms)
    Dose 1.3 nGy – 650 Gy. 150 nR – 74 kR. (±5 %)
    Dose Rate 15 nGy/s – 320 mGy/s (±5 % or ±7 nGy/s)
    1.7 μR/s – 37 R/s (±5 % or ±0.8 μR/s)
    Auto Compensation All dose parameters are automatically compensated for using measured kVp and TF over their specified ranges.
    HVL 0.72 – 13 mm Al (±10 % or ±0.2 mm)
    Total Filtration 1.0 – 90 mm Al (±10 % or ±0.3 mm)
    Pulses 1 – 65535 pulses (±1 pulse)
    Dose/pulse 8 nGy/pulse – 0.9 Gy/pulse
    Pulse Rate/Frequency 0.5 – 180 Hz
    Pulse width 4 ms – 2000 s
  3. Tube Voltage
    Target/Filter: Mo / 30 μm Mo
    Range: 18 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target/Filter: Mo / 25 μm Rh
    Range: 20 – 46 kV
    Inaccuracy: ±1 kV
    Target Filter: Rh / 25 μm Rh
    Range: 25 – 49 kV
    Inaccuracy: ±1 kV
    Target Filter: Rh / 1.0 mm Al
    Range: 22 – 35 kV
    Inaccuracy: ±1 kV
    Target Filter: W / 50 μm Rh
    Range: 20 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %0,
    Target Filter: W / 0.50 mm Al
    Range: 20 – 48 kV
    Inaccuracy: ±1 kV
    Target Filter: Mo / 1.0 mm AI
    Range: 18 – 49 kV
    Inaccuracy: ±1 kV
    Target Filter: W / 50 μm Ag
    Range: 20 – 40 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: W / 75 μm Ag
    Range: 20 – 40 kV
    Inaccuracy: ±1 kV
    Target Filter: W / 50 μm Rh (Gio)
    Range: 22 – 35 kV
    Inaccuracy: ±1 kV
    Target Filter: W / 50 μm Rh (Gio)
    Range: 22 – 35 kV
    Inaccuracy: ±1 kV
    Target Filter: W / 0.70 mm Al
    Range: 20 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: W / 50 μ m Ag (Sel)
    Range: 22 – 39 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: W / 50 μ m Rh (Sel)
    Range: 22 – 39 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: W / 0.30 mm Cu
    Range: 40 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: W / 0.70 mm Al (Inno/Crist)
    Range: 20 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: W / 50 μ m Rh (Inno/Crist)
    Range: 20 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: Mo / 25 μ m Rh (Sel)
    Range: 20 – 46 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: Rh / 30 μm Ag (GE)
    Range: 27 – 40 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: Rh / Ag IQST (GE)
    Range: 31 – 37 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: Mo / 0.25 mm Cu (GE)
    Range: 40 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: Rh / 0.25 mm Cu (GE)
    Range: 40 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter:Mo / 30 μm Mo (GE)
    Range: 22 – 32 kV
    Inaccuracy: ±1 kV
    Target Filter: Affirm Prone W / 50 μm Ag
    Range: 20 – 40 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Target Filter: Affirm Prone W / 0.70 mm Al
    Range: 20 – 49 kV
    Inaccuracy: ±0.5 kV or ±1.5 %
    Time 0.1 ms – 2000 s (±0.5 % or ±0.5 ms)
    Dose 1 nGy – 1000 Gy. 3 µR – 150 kR (±5 %)
    Dose Rate 25 nGy/s – 530 mGy/s (±5 % or ±12 nGy/s)
    30 μR/s – 60 R/s (±5 % or ±1.5 μR/s)
    HVL Range 0.19 – 4.3 mm Al (depending on Target/Filter combination) (±10 %)
    Pulse 1 – 65535 pulses (±1 pulse)
  4. Tube Voltage 45 – 155 kV (±1.5 %)
    Time 0.1 ms – 2000 s (±0.5 % or ±0.5 ms)
    Total Filtration 1 – 90 mm Al (±10 % or ±0.3 mm)
    HVL 1.2 – 14 mm Al (±10 % or ±0.2 mm)
    Pulses 1 – 65535 pulses (±1 pulse)
  5. Tube Voltage 35 – 125 kV (±1.5 %)
    PPV Yes
    Time 0.1ms – 2000 s (±0.5 % or ±0.5 ms)
    Dose 1.3 nGy – 650 Gy. 150 nR – 74 kR. (±5 %)
    Dose Rate 15 nGy/s – 320 mGy/s (±5 % or ±7 nGy/s). 1.7 μR/s – 37 R/s (±5 % or ±0.8 μR/s)
    Auto Compensation All dose parameters are automatically compensated for using measured kVp and TF over their specified ranges.
    HVL 1.2 – 14 mm Al (±10 % or ±0.2 mm)
    Total Filtration 1.0 – 90 mm Al (±10 % or ±0.3 mm)
    Pulses 1 – 65535 pulses (±1 pulse)
    Dose/pulse 8 nGy/pulse – 0.9 Gy/pulse
    Pulse Rate/Frequency 0.5 – 180 Hz
    Pulse width 4 ms – 2000 s
  6. Size 20 x 45 x 7.4 mm, 0.79" x 1.8" x 0.29"
    Weight 85 g (3 oz)
    Cable length 2.0 m (6.6 ft)
    Backscatter protected Yes
    Dose 100 pGy – 1.5 kGy. 12 nR – 170 kR (± 5%)
    Dose Rate 4 nGy/s – 150 mGy/s (±5 % or ±10 nGy/s).
    0.46 μR/s – 16 R/s (±5 % or ±1 μR/s).
    26 μR/min – 1000 R/min (±5 % or ±6 μR/min).
    Time 0.1 ms – 34000 s (±1 % or ±0.5 ms)
    Pulses 1 – 65535 pulses (±1 pulse)
    Dose per pulse 1 nGy/pulse – 0.3 Gy/pulse
    Pulse rate/frequency 0.5 – 100 Hz
    Pulse width 4 ms - 2000 s
  7. Type MAS-1B
    Current range 0.1–3000 mA
    Inaccuracy ±1 % or ±0.01 mA
    Frequency range DC–500 Hz (-3 dB)
    Size 60 x 35 x 72 mm
    Weight 125 g
    Battery life Around 100 h
    Rechargeable battery With mini-USB connector
    Cable length 4 m (extension available)
    Connector Hirose
  8. Type MAS-2
    Current range 10 - 4000 mA
    Inaccuracy ±5 % or ±2 mA (±3 % at 250 mA)
    Charge range 0.1 mAs - 9999 mAs
    Size 183 x 61 x 36 mm
    Connector Hirose
    Maximum cable diameter 24 mm
    Power source 9 V "6LR61" Alkaline battery
  9. Dose rate range 67 nGy/s-2.2 Gy/s. 0.46 mR/min - 15000 R/min
    Inaccuracy ±5 % or ±15 nGy/s
    Spatial resolution 0.25 mm
  10. Air kerma rate 0.3 mGycm/s to 3 Gycm/s
    Inaccuracy ±5 % or ±0.03 mGycm/s
    Connector type LEMO triaxial
    Cable 2 m, low noise triaxial
    Active volume 16 cm³
    Active length 300 mm
    Diameter 12 mm, 12.6 incl O-rings
    Typical leakage ±20 fA
    Radiation quality 70 - 150 kV
    Sensitivity 30 mGycm/nC
    Energy Dependence ±1 %

LoniMoverâ„¢

Measure CTDI for Wide Beam and Cone Beam CT! Together with the RTI CT Ion Chamber or CT Dose Profiler, the RTI LoniMoverâ„¢ is, without a doubt, the easiest and most accurate way to measure CTDI and waveforms for Wide Beam and Cone Beam CT. With the CT Dose Profiler, you will get the FWHM, [...]

Read more

CTDI Phantom Set

Adapt the size of the phantom RTI CTDI Phantom Sets simulates adult and pediatric head and body of patients for QA testing of ­computed tomography (CT) systems. RTI offers two different CTDI Phantom sets. Choose two (2) or three (3) parts. Both have nested modules to allow adaptation to the size required by the selected [...]

Read more

Piranha Panoramic Holder/Vertical Holder v.4

Attach your Piranha vertically The Piranha Panoramic Holder/Vertical Holder v.4 is designed for attaching the Piranha DENTAL meter to dental panoramic equipment or vertical mounting. It can be mounted with an adjustable strap or magnets. [...]

Read more

10" Tablet PC 

Connect wirelessly! Microsoft Surface Go 3 10″ Tablet PC display for wireless or USB communication with the Piranha, Mako and Cobia meters. The portable tablet comes with a detachable keyboard, Windows 11 Home, installed Ocean Nextâ„¢ software, built-in Bluetooth, a charger, and all necessary items to make it a user-friendly & versatile [...]

Read more